5000W pure sine wave power inverter 48V to 220V/120V / battery charger / LCD
Series: | 5000W pure sine wave power inverter 48V GI Series |
Feature 1: | Toroidal pure copper transformer, over 92% efficiency, idel consumption less than 0.5A |
Feature 2: | Low failure rate, less than 0.2% |
Feature 3: | 64-bit high-speed DSP smart chip, fast reaction, transfer time less than 4ms. |
Feature 4: | double filter,pure sine wave output |
Feature 5: | application: solar system, back up power system, wind system |
DESCRIPTION
5000W pure sine wave power inverter 48V to 220V/120V / battery charger / LCD
Product features:
1. 3 times peak power, excellent loading capability
2. Bulit-in AVR stablizer, supply the continuous stable outpout.
3. Toroidal transformer, working efficiency more than 92%
4. Tranfer time ≤ 4ms
5. LCD display with multi-function buttons.
6. Pure sine wave output wave form, input and output isolation design
7. Intelligent fan (Automatically adjust rotating speed according to the internal temperature)
8. Perfect protection against low voltage, over voltage, short circuit, over load and over temperature etc.
Technical specs:
Model | GI-102 | GI-152 | GI-202 | GI-302 | GI-402 | GI-502 | GI-602 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
Nominal battery | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
AC Mains input range | 145-265VAC (220/230/240VAC)±4% | |||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
Over load protection | 110%150%, shutdown after 20s alarm | |||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
Short circuit protection | Automatic shutdown | |||||||
Output | Transfer efficiency | ≥92% | ||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
Output frequency | (DC battery mode) 60/50Hz±1% | |||||||
Output wave form | Pure sine wave | |||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
Other | Transfer time | Bult- in AC bypass replay (≤4ms) | ||||||
Display | LCD Display with function buttons | |||||||
Cooling system | Intelligent cooling fan control system | |||||||
≤42℃ slow fan, ≥45℃ fast fan | ||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Calcium(open) | ||||||
Deep sulphation cycle 15.5 for 4 hrs | ||||||||
AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||
AC charging current | 0-35A: 5A / 10A / 20A / 25A / 30A / 35A, 6 stages charging current adjustable | |||||||
3 Stages charging | Boost charging, direct charging, float charging | |||||||
AC over charge protection | Battery voltage ≧16VDC (12V) ≧32VDC (24V) ≧64VDC (48V), stop charging after 60s alarm | |||||||
Working mode optional | 01 | AC mains priority | ||||||
Always use AC mains as priority input to provide AC output and automatically charge the battery | ||||||||
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off | ||||||||
02 | Energy saving | |||||||
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on | ||||||||
03 | DC battery priority | |||||||
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, starts | ||||||||
DC to AC converting; when battery≤10.5V during converting, switch to AC mains mode to provide AC | ||||||||
output and automatically start charging the battery (for 24V/48V system, multiply by 2/4 accordingly) | ||||||||
Comnunication | RS-232/USB/SNMP(additional option) | |||||||
Environment | Temperature | -20~+75℃ | ||||||
Humidity | <95% | |||||||
Appearance | Product size (mm) | 460*245*200mm | 630*280*200mm | |||||
Packing size (mm) | 530*335*255mm | 740*355*275mm | ||||||
Net Weight (kg) | 11.2kg | 13.2kg | 14.8kg | 16.8kg | 25kg | 28kg | 32.5kg | |
Gross Weight (kg) | 13.5kg | 15.5kg | 17.1kg | 21.8kg | 28.4kg | 31.5kg | 35.9kg | |
*Product specifications are subject to change without further notice |