MPPT solar charge controller 20A- 80A
Series: | high efficiency MPPT solar regulator controller |
Feature 1: | The efficiency is up to 99% |
Feature 2: | Intelligent DSP control chip |
Feature 3: | Intelligent LCD display with multi-function |
DESCRIPTION
MPPT solar charge controller 20A- 80A
Product features:
A. The efficiency is up to 99%
B. Intelligent DSP control chip
C. Intelligent LCD display with multi-function
D. Switching power is supplied by independent system
E. True Over Temperature Protection
H. New and original electronic components
I. Internal circuit lines and signal lines are based on plug-pull blocks, not welding
Model | LI-702 | LI-103 | LI-153 | LI-203 | |
Rated Power | 7KW | 10KW | 15KW | 20KW | |
Peak Power | 21KW | 30KW | 45KW | 60KW | |
Nominal battery voltage | 96VDC | 192VDC | |||
Input | DC input range | 84-120VDC (96V) / 168-240VDC (192V) | |||
AC Mains input range | (220/230/240VAC) 140-275VAC | 170-250VAC | |||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) | ||||
Protection | Low battery alarm | ≤84VDC (96V) / ≤168VDC (192V) alarm | |||
Low battery protection | ≤80VDC (96V) / ≤160VDC (192V) automatic shutdown | ||||
High battery alarm | ≥120VDC (96V) / ≥240VDC (192V) alarm | ||||
High battery protection | ≥136VDC (96V) / ≥272VDC (192V) automatic shutdown | ||||
Over load protection | 110% more than rated capacity, automatic shutdown | ||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown |
||||
Short circuit protection | Automatic shutdown | ||||
Output | Transfer efficiency | ≥85% | |||
Output voltage | (DC battery mode) 220/230/240VAC±2% | ||||
Output frequency | (DC battery mode) 60/50Hz±1% | ||||
Output wave form | Pure sine wave | ||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
||||
AVR output stablizer | AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; |
||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
|||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
|||||
Output frequency | (AC mains mode) automatic tracing from AC input | ||||
Other | Transfer time | Bult- in AC bypass replay (≤4ms) | |||
Display | LCD Display with function buttons | ||||
Cooling system | Intelligent cooling fan control system | ||||
≤42℃ slow fan, ≥45℃ fast fan | |||||
AC Charger | AC charging Voltage | /108.8-113.6VDC(96V)/217.6-227.2VDC(192V) | |||
AC charging current | Steady 15A | ||||
AC over charge protection |
Battery ≧128V (96V) ≧256V (192V), stop charging after 60s alarm | ||||
Working mode optional |
01 | AC mains priority | |||
Always use AC mains as priority input to provide AC output and automatically charge the battery |
|||||
stops charging when battery is fully charged, and only starts DC to AC converting untill AC mains is off |
|||||
02 | Energy saving | ||||
Loading≤10% automatic shutdown, loading≥11%-100% automatic turn on | |||||
03 | DC battery priority | ||||
Always use DC battery as priority input to provide AC output, for 12V system, when battery≥13V, |
|||||
starts DC to AC converting; when battery≤84V during converting, switch to AC mains mode to provide AC output and |
|||||
when battery≤84V during converting, switch to AC mains mode to provide AC output and |
|||||
Comnunication | RS-232/USB/SNMP(additional option) | ||||
Environment | Temperature | -20~+75℃ | |||
Humidity | <95% | ||||
Appearance | Product size (mm) | 485*300*655mm | |||
Packing size (mm) | 623*385*709mm | ||||
Net Weight (kg) | 57kg | 85kg | 105kg | 125kg | |
Gross Weight (kg) | 72kg | 100kg | 120kg | 140kg | |